Dental Lab Communication Checklist for Dentists

Dental Lab Communication Checklist for Dentists

By Dr. Kellen McWhorter, Prosthodontist
Last updated: November 2026 · Clinically reviewed by Dr. Kellen McWhorter, Prosthodontist


Most dental lab remakes trace back to communication gaps that could have been prevented in 90 seconds at Rx submission. This 10-minute checklist walks through the information every lab needs on every case, when to pick up the phone instead of writing it, and the five Rx fields that most practices leave blank.

Print it. Tape it next to your lab prescription station. Use it on your next case.


Why Communication Is the #1 Cause of Lab Remakes

Industry reports suggest typical US lab remake rates run between 5 and 15 percent, depending on case type. The share tied to fabrication alone is small. The majority of remakes trace back to missing information, unclear preferences, or a prep decision the lab had to guess at.

Think about where remakes actually start. A shade note that says “A2” with no photo. A bite registration that captured a slide, not centric. A margin the scan never fully showed. An opposing arch that was skipped because the operatory was behind schedule. None of these are fabrication issues. They are communication issues.

The good news is that most of them are fixable at submission. A disciplined Rx process, run on every case, prevents more remakes than any single piece of lab technology. For a deeper look at why remakes happen and how to lower the rate, see our breakdown on how to reduce crown remakes.


The Universal Rx Checklist (Every Case, Every Lab)

These are the fields that belong on every prescription, every time, regardless of what lab you send to or what restoration you ordered. If any one of them is missing, the lab is guessing.

  • Patient name and case number. Confirms chain of custody. Prevents cross-case mix-ups when the lab batches work.
  • Tooth number and specific restoration. Crown, bridge, veneer, inlay, onlay, implant crown, or screw-retained prosthesis. “Crown on #14” is not the same prescription as “zirconia implant crown, screw-retained, on #14.”
  • Material. Zirconia, lithium disilicate (e.max), PFM, feldspathic porcelain, hybrid. If you have a preferred shade of zirconia or a specific generation of e.max, name it. Labs stock several and will choose the wrong one if you leave it blank.
  • Shade, with photos. Write the shade (for example, A2 cervical, A1 incisal). Then include two photos: the shade tab held next to the prepped tooth, and the shade tab held next to the ipsilateral comparison tooth. Natural daylight. No overhead op light. No gloves in frame.
  • Contact preference. Tight, light, or open. Name the adjacent teeth and whether you want the mesial and distal matched to the ipsilateral comparison tooth.
  • Occlusal clearance available. Note the reduction you measured. If clearance is tight, say so. A lab that knows clearance is limited will design differently than one that assumes textbook reduction.
  • Prep photos. Facial, occlusal, and lingual at minimum. Probing depths if the tooth has periodontal history. Retracted photos with the margin visible beat intraoral scans every time for communicating the finish line.
  • Opposing arch scan or impression. Not optional. A single-unit crown designed without the opposing arch is a crown designed in a vacuum.
  • Bite registration. Confirm centric. If the patient has a slide, note it. If you took the bite in MIP, say so. If you took it in centric relation, say that.
  • Stain and characterization preferences. Blended, high-value, matched to adjacent restorations, or clinician choice. Leaving this blank gets you the lab’s default aesthetic, which may not match your practice standard.

This is the floor. A case missing any of these fields is a case the lab is going to call back on, and every callback adds a day to turnaround.


Case-Specific Fields That Most Dentists Leave Blank

The checklist above covers what every lab asks for. The following fields are not usually printed on a default Rx form, but they prevent the most frustrating remakes, the ones where the restoration is technically fine but the patient (or you) looks at it and says it is not right.

  • Vertical dimension of occlusion (VDO) notes. If you are opening the bite, closing it, or holding existing VDO, write that out. On full-arch and multi-unit cases this is the single highest-leverage field on the form.
  • Lip support preferences. On anterior cases, note whether the patient needs more labial support, less, or match-existing. A smile photo at rest and a smile photo full-smile helps the ceramist decide incisal edge position.
  • Canine prominence. Flat, slightly prominent, dominant. Patients who used to have strong canines and have worn them down often read a flat canine as “not my teeth.”
  • Prior restoration history on adjacent teeth. If #8 was crowned three years ago and you are now crowning #9, the lab needs to know what shade system the #8 was built on, which lab did it, and what the material was. Matching a crown next to an older restoration is a different design problem than crowning the first tooth in a quadrant.
  • Patient’s own aesthetic preferences. Some patients want youthful, bright, high-value restorations. Some want their restoration to disappear into their existing dentition. Ask. Write the answer on the Rx.

These are the fields that separate a correct restoration from the right restoration. A lab that is capable of using them, and that asks for them if you forget, is a lab that is treating your case as a clinical problem, not a production order.


Scan or Impression Submission Standards

Digital workflow is standard across most of the US dental lab market now, but the information the lab needs is identical regardless of the capture method. Here is the standard, applied fairly to both.

For intraoral scans:

  • Full 360-degree margin visibility on the prepped tooth. If the margin is subgingival, retract and rescan. Do not submit a scan where the margin is implied.
  • Adjacent teeth captured one tooth distal and one tooth mesial at minimum.
  • Full opposing arch, not a quadrant scan. The lab needs the full arch to design posterior contacts.
  • Stable bite registration captured in the same session.
  • For implants: a verified scan body with the correct implant platform called out in the Rx. Include a photo of the scan body seated.

For traditional PVS impressions:

  • Full-arch impression preferred over quadrant for anything above a single-unit posterior.
  • Clean margin captures with no voids, drag marks, or blood contamination.
  • Bite registration in a stable material (not wax).
  • Impression date on the box, so the lab knows set time has passed before pouring.
  • For implants: an open-tray impression with a verified transfer. Note the implant system, platform, and whether the connection is internal or external.

Both methods work. Both methods fail when the fundamentals are skipped. If you want a longer discussion of how scan-based margin design changes prep expectations, see crown margins from a lab perspective.


When to Call the Lab Instead of Writing It

Written prescriptions work for routine cases. There are seven situations where a two-minute phone call will save you more time than the longest Rx note ever could.

  1. Full-arch cases. Any full-arch provisional, final, or conversion case. The lab needs to understand the clinical sequence, the patient’s expectations, and the operative plan. For the longer sequence, see our full-arch implant workflow checklist.
  2. Complex esthetic cases. Any anterior case where shade mapping, characterization, or incisal effects need a conversation. A photo and a shade tab are not enough on their own.
  3. Remakes. Call before you resubmit. The lab needs to know what seated wrong, what you adjusted, and what you want different on version two. A silent remake almost always produces a second remake.
  4. Patients with a history of failed restorations. If this is the patient’s third attempt at a restoration on the same tooth, the lab needs to know. The design question changes.
  5. VDO changes. Any case that opens, closes, or restores vertical dimension of occlusion. A ten-minute call upfront prevents a two-week rebuild downstream.
  6. Non-standard material requests. If you are asking for a material the lab does not run every day, confirm by phone. Confirm availability, lead time, and whether a certified technician is on-staff for that product.
  7. Time-sensitive cases. Any case tied to a travel date, a wedding, a graduation, a surgery, or any other calendar-anchored event. Say so, confirm the lab can meet the date, and get the commitment in writing.

A written Rx captures what. A phone call captures why. Complex cases need both.


How to Read a Lab’s Response and What to Ask Back

When a lab calls or messages for clarification, the question itself tells you what was missing. Read it as diagnostic feedback on your submission.

  • “What shade are the adjacent teeth?” Your shade note was isolated. Next time, send comparison photos with the shade tab next to the ipsilateral tooth, not just the prepped tooth.
  • “Can you confirm the bite?” Your registration did not match the scans or the models. Rescan the bite or re-register.
  • “What material do you want?” The Rx said “crown” without specifying zirconia, e.max, or PFM. Add it to your standing template.
  • “Do you want this stained to match #8 or blended with the arch?” Characterization was left blank. Decide once, write it on every anterior Rx going forward.
  • “What is the opposing dentition?” You skipped the opposing arch scan. Never skip it, even on single units.

Over a quarter, the clarification questions you receive are a map of the fields you leave blank. Patch those fields and your callback rate drops. For a longer look at how case planning conversations are structured, see our dental lab case planning guide.


The One-Page Peak Rx Template

At Peak Dental Studio, the Rx is treated as a clinical document, not a shipping label. Every case we accept carries the fields above as a floor, with a named technician assigned at submission and reachable by phone throughout fabrication. Here is the one-page template we use internally. You are welcome to adapt it for any lab.

  1. Patient name, case number, submission date, due date.
  2. Tooth number(s), restoration type, material, shade with photos.
  3. Contact and occlusal preferences, with comparison tooth named.
  4. Opposing arch, bite registration, prep photos (facial, occlusal, lingual).
  5. Case-specific fields: VDO notes, lip support, canine prominence, prior restoration history, patient aesthetic preferences.
  6. Capture method confirmation: scan platform and file export, or PVS tray, material, and set time.
  7. For implants: implant system, platform size, connection type, scan body or open-tray transfer confirmation.
  8. Named technician on the Peak side (filled in by the lab, visible to the dentist).
  9. Dentist’s direct phone and preferred contact method.
  10. One free-text box for anything the fields above do not capture.

Signature Case Ownership means one named technician holds your case from digital design through final stain. That is the context behind the template above. If you want to see how that model handles implant and full-arch cases, our digital dental lab page lays out the workflow in more detail. And if a case ever has to pause mid-fabrication, our dental lab case on hold checklist covers how to communicate that cleanly.


Frequently Asked Questions About Dental Lab Communication

What is the single most important field on a dental lab Rx?
If forced to pick one, it is the shade note paired with photos. Shade decisions constrain every downstream design choice, and shade is the field most often written as a single letter-and-number code with no supporting image. A written shade plus two photos (prepped tooth with tab, ipsilateral tooth with tab) prevents a large share of anterior remakes.

How often do communication gaps cause lab remakes?
Industry reports suggest the majority of remakes trace back to communication rather than fabrication. The exact percentage varies by case type and lab, but on anterior and full-arch cases, communication-driven remakes typically outnumber true fabrication defects by a wide margin.

Should I send photos even for routine posterior crowns?
Yes. Even a single occlusal and a single facial photo helps the lab verify the margin and the adjacent dentition. Photos cost 30 seconds at the chair and save hours of back-and-forth on cases where the scan or impression is ambiguous.

What is the right way to communicate a bite registration issue?
Call the lab before you resubmit. Describe what the bite captured (centric, MIP, protrusive) and what you want the lab to use. If the patient has a slide, note the direction and magnitude. Written notes alone rarely resolve bite questions because the lab cannot see the patient.

Can a scan replace prep photos?
No. A scan shows geometry, not clinical context. Prep photos communicate margin location, tissue response, blood or saliva control, and the condition of the adjacent dentition. The lab uses both together, and dropping either one weakens the submission.

How much detail does the lab need on patient preferences?
As much as the patient has given you. If the patient said they want their new restoration to look like their old teeth did, write that down. If the patient wants brighter, write that. If the patient has no opinion, write that. The absence of a note is read as “clinician choice,” which may not match what the patient asked for.

What should I do if my current lab does not use a structured Rx?
Send one anyway. Build your own one-page Rx template using the fields in this article, keep a stack at the submission station, and attach it to every case regardless of what the lab’s intake form looks like. The lab will adapt to the sender who sends the most useful information.

How do I know if my lab communication is actually improving?
Track two numbers over a quarter: your clarification-call rate and your remake rate, both as a share of total cases submitted. If both drop after you implement a structured Rx, the communication change is doing its job. If only one drops, inspect which fields the lab is still asking about and tighten those.


Try Peak on a Sample Case

If this checklist describes how you already run your lab prescription station, we would like to see a sample case. One named technician, pay-per-case pricing, and no scanner lease. Signature Case Ownership from the first submission.

Send a Sample Case →   Learn About Case Planning →


About the author. Dr. Kellen McWhorter is a board-eligible prosthodontist and the clinical lead at Peak Dental Studio in Pleasant Grove, Utah. His work focuses on implant, full-arch, and complex esthetic restorations, and on the lab-dentist communication protocols that make those cases predictable. Read more at Dr. Kellen McWhorter, Prosthodontist.

Before you go: Get Peak's 2026 price book.

Send me the price book

Your Privacy Choices

Choose what this site may use on this browser. Your choices are saved on this browser and device only. If you use another browser or clear your cookies, choose again. A Global Privacy Control signal from your browser always turns advertising off.

Cookie and tracking choices

Your choice applies to this browser and takes full effect on the pages you open after you choose. Pages of our site already open in other tabs may need a reload. Opting out does not remove information our ad partners already received. You may still see our ads, but they will not be based on what you do on our site in this browser after you opt out. Learn more in our Privacy Policy.