Smile Design Workflow: From Wax-Up to Final Stain
By Dr. Kellen McWhorter, Prosthodontist
Last updated: November 2026 · Clinically reviewed by Dr. Kellen McWhorter, Prosthodontist
A predictable smile-design case moves through seven steps: diagnostic records, digital smile design, diagnostic wax-up, mock-up try-in on the patient, prep guide fabrication, provisional restoration, and final try-in before cement. Each step produces a decision the patient and the dentist must sign off on before the lab moves forward. Skip a step and the risk of a remake at seat compounds.
We wrote this article for the general dentist or cosmetic-focused practice collaborating with a lab. The sequence applies to a two-unit midline rebuild or a ten-unit smile makeover alike. (See also How to Photograph Shade for Dental Lab Cases and Signature Veneers.)
Why Smile-Design Cases Fail
Four failure modes create most remakes on cosmetic cases. If you have ever reshaped a veneer at seat or heard a patient say “it’s just not what I pictured” at try-in, one of these is usually in play.
- No diagnostic wax-up. The case jumped from consultation to prep without a physical artifact the patient could react to. The patient reacts to the final ceramic, which is the most expensive moment to find out a tooth is too long.
- No patient-approved mock-up. A wax-up was fabricated, but the patient never tried it on. The dentist approved the design. The patient had never seen it in their own mouth.
- VDO decided after prep instead of before. Vertical dimension of occlusion (how far apart the jaws are at rest, abbreviated VDO) was adjusted during provisional. Any change at that stage ripples through every subsequent step.
- Incomplete shade communication. Shade was recorded as a single tab name on the lab slip, with no photographs and no notes on value, chroma, or translucency. (See Why Crowns Come Back the Wrong Shade.)
The workflow below prevents every failure mode above. It is a sequence of decisions, each one captured in writing or in a photograph, each one approved by the person who owns the outcome.
Step 1: Diagnostic Records
The lab needs enough information on day one to design the case without asking for records twice. A complete records packet includes:
- Full-face smile photo. Lips parted, teeth showing, natural head position. The lab needs to see how the smile sits inside the face.
- Retracted frontal. Lips retracted, teeth together in maximum intercuspation.
- Retracted lateral. One image per side, showing the posterior occlusal plane and canine-to-canine curve.
- Occlusal maxillary and mandibular. Mirror shots of each arch. The lab reads arch form and symmetry from these.
- 1:1 close-up with shade tab. At least one shade photograph with the tab held edge-to-edge against the target tooth, in polarized or cross-polarized light.
- Radiographs or CBCT if available. A recent panoramic plus periapicals of the anterior sextant. CBCT helps on cases involving implants or crown-lengthening.
- Scan or impression of both arches. Intraoral scan preferred, polyvinyl impression acceptable. Full-arch, not just the anterior.
- Bite registration. Centric relation or maximum intercuspation, labeled clearly.
- VDO measurement and notes. Current vertical dimension of occlusion, any history of wear, and whether the case will open the bite.
Without a full-face smile photo, the lab cannot design a case to the face. The temptation to send partial records and backfill later tends to be where remakes start.
Step 2: Digital Smile Design or 2D Smile Mockup
The design phase is where the proposed smile is drawn and visualized against the patient’s face before any wax is touched.
Practices with a digital smile design (DSD) workflow use software such as Keynote, Smilecloud, exocad DentalCAD, or 3Shape Smile Design to overlay proposed tooth positions on the full-face smile photograph. The design is referenced against facial midline, interpupillary line, incisal edge position, and canine-to-canine proportion.
Practices without a DSD setup can still do a 2D smile mockup: a side-by-side composite of the full-face smile photograph next to a drawn proposal of the new tooth positions, assembled in a free image editor or slide program. Less interactive than DSD, but it still gives the patient something to react to.
Division of responsibility: the lab interprets the prescription and translates it into a design that can be fabricated. The dentist owns the clinical case, including midline, incisal edge position, VDO, occlusal scheme, and final patient approval. On a Signature case at Peak, our ceramist sends design options and asks questions when the records leave a judgment call open.
Step 3: Diagnostic Wax-Up
The wax-up is the physical object the patient will experience through the mock-up try-in. It is the first time the proposed design leaves the screen and lives in three dimensions.
The lab fabricates the wax-up on mounted models, from the approved digital or 2D design. Three materials are common:
- Hand wax. Built up tooth by tooth by a technician. Favored for fine control on cases where contours matter at the tenth of a millimeter.
- Milled PMMA. Polymethyl methacrylate (a hard tooth-colored acrylic) milled from the digital design. Fast, repeatable, and holds surface detail well.
- 3D-printed resin. Printed from the design file, trimmed and polished. The fastest option on multi-unit cases.
For a Signature veneer case, we tend to print or mill the wax-up because the digital record carries forward unchanged into the prep guide and provisional stages. For a highly artistic single-tooth case, hand wax may give the ceramist a better feel for contour. Turnaround is typically one to two weeks from records approval. For more detail on this stage, see Diagnostic Wax-Ups and Treatment Planning.
Step 4: Mock-Up Try-In on the Patient
This is the single most important step in the workflow. The team converts the wax-up to a bisacryl mock-up in the patient’s mouth, and the patient looks in a mirror at the proposed smile on their own face.
Most practices use the bisacryl shell technique. Next, take a silicone matrix off the wax-up. Bisacryl (a tooth-shade composite that sets in a few minutes) is loaded into the matrix, the matrix is seated over the untouched teeth, and the mock-up releases as a thin shell on the natural dentition. No prep, no bonding. The patient can speak, smile, and photograph.
What to capture while the mock-up is in:
- Full-face smile photographs matching the baseline angle.
- Retracted frontal and laterals.
- A short video of the patient speaking words that show incisal edge position (“fifty-five” is a classic for F-sound lip contact).
- The patient’s verbal reaction and any changes requested, documented in the chart.
Expect one to two revision cycles on complex anterior cases. The first mock-up almost never ships straight to prep. The patient may ask for shorter central incisors, more rounded canines, or a different incisal embrasure. Each change goes back to the lab as a specific note tied to a specific tooth. Revisions here are far less expensive than revisions after the ceramist fires the ceramic.
Step 5: Prep Guide
Once the mock-up is approved, the lab fabricates a reduction guide, also called a prep guide, from the approved wax-up. You use the guide chairside to control how much tooth structure you remove during preparation.
Two formats are common: a silicone matrix (a clear or opaque impression of the approved wax-up, often sectioned into facial and incisal pieces), and a 3D-printed reduction guide (a rigid shell that fits over the arch with cut-outs showing target reduction depth at the facial, incisal, and interproximal walls).
Chairside use, in brief: place depth-cut grooves at facial and incisal referenced against the guide, rough prep to the depth cuts, reseat the guide to verify reduction at every surface, then refine margins and record final margins with a scan or impression.
The point of the prep guide is to prep to the design, not to prep first and hope the design fits what is left of the tooth. Under-reduced teeth produce overcontoured ceramics. Over-reduced teeth produce weaker remaining structure. The guide is a cheap insurance policy against both.
Step 6: Provisional Restorations
This provisional is a long-term temporary milled or fabricated from the approved design. The patient wears it for two to six weeks on esthetic cases and tests the design under real conditions: eating, speaking, smiling, living with their own face day after day.
What the provisional phase accomplishes:
- Esthetic sign-off under daily use. A patient who approved the mock-up in a 20-minute visit may feel differently after two weeks of living with it.
- Functional sign-off. The provisional carries the proposed occlusal scheme and VDO. Any issues with speech, chewing, or TMJ should surface here.
- Tissue response. The gingiva responds to the emergence profile. The lab reads tissue health off photographs at a two-week recall.
- Reference for the final. Photographs of the approved provisional go back to the lab as the final design reference.
Common materials are milled PMMA and bis-acryl. Milled PMMA holds up longer and resists staining better on a six-week wear. Sign-off should be captured in a chart note, photographs matched to the baseline angles, and a copy sent to the lab with any final revisions.
Step 7: Final Try-In and Seat
The final try-in is the step most often skipped on busy cosmetic cases, and the one most often responsible for a remake at seat. On a ceramic case, the lab delivers restorations at the bisque stage (fired but not fully glazed) so the dentist can try them in, verify shade and fit against the natural dentition, and request stain or glaze adjustments before final firing.
What to verify at bisque try-in:
- Marginal fit at every unit.
- Interproximal contacts, confirmed with floss.
- Occlusal contacts, confirmed with articulating paper.
- Shade match against the natural dentition under multiple light sources.
- Patient approval, confirmed with a mirror and ideally a photograph.
Shade confirmation photographs at bisque try-in go back to the ceramist as instructions for final stain. Common lab-facing notes read like “increase chroma at the cervical third of #8 and #9, add a small incisal halo at #9 to match the natural asymmetry of #8.” The more specific the note, the less guesswork at final stain.
After bisque approval, the lab stains, glazes, and returns the restorations for cementation. Materials commonly used on esthetic cases include lithium disilicate (eMax) for single-unit and short-span anterior work, and layered zirconia for cases that need higher strength under esthetic demands. See eMax Ceramic Restorations for material selection considerations.
Lab-Side Workflow Expectations
What a lab should bring to each phase, in short:
- Design. A named ceramist who owns the case start to finish and can be reached by phone or chat. At Peak, this is Signature Case Ownership: one technician per case.
- Wax-up. Fabricated from the approved design, delivered with a silicone matrix for the chairside mock-up.
- Mock-up revisions. Specific, tooth-by-tooth revisions turned around in a few days.
- Prep guide. Delivered with the wax-up or shortly after, in silicone or printed format.
- Provisional. Milled from the approved design file so the final restoration carries the same geometry forward.
- Final try-in. Delivered at bisque, with the ceramist available to interpret stain and glaze notes before final firing.
A lab’s role on a cosmetic case is to make the dentist look like the artist. The ceramist works inside the design the dentist approved and inside the sign-off the patient gave.
Common Communication Gaps That Cause Smile-Design Remakes
If a case comes back for a remake, the cause is almost always traceable to a communication gap earlier in the workflow. The ones we see most often:
- Shade tab name on the Rx with no photographs. A tab name alone cannot carry value, chroma, translucency, or surface texture. The lab must guess.
- Mock-up photographs skipped. The dentist approved chairside but sent no photographs. The lab fabricates to the original design, which may not match what was actually agreed on.
- Revisions sent as “make it look better.” Revisions must name tooth number, surface, dimension, and target. “Shorten #8 and #9 by 0.5 millimeters at the incisal edge” is actionable. “A little less toothy” is not.
- VDO changes mid-case. If the bite opens or closes between design and prep, the case may need to be redesigned. Decide VDO before records.
- Provisional changes not reported. The dentist adjusts the provisional chairside and the patient approves the new shape, but the lab never receives the update.
- Final try-in skipped. The lab delivers fully glazed ceramics and the dentist seats without a bisque try-in. Any shade or shape issue at that point is a remake, not a revision.
For the lab-side view of what these gaps produce at the bench, see Best Dental Lab for Veneers.
FAQ About Smile Design Workflow
How long does a full smile-design case take from first consult to final seat?
On a standard anterior case of six to ten units, expect eight to twelve weeks from records to final seat. The timeline includes wax-up fabrication, one to two mock-up revision cycles, prep and provisional, two to six weeks in provisional, and a bisque try-in. Cases involving orthodontics, crown-lengthening, or implants extend the timeline.
Can a case skip the diagnostic wax-up and go straight to prep?
Technically yes, and it is a reliable way to produce a remake. The wax-up is the only tool that lets the patient react to the proposed design before the teeth are prepared. On a single posterior crown it may be unnecessary. On any anterior case where esthetics drive the result, skipping it tends to cost more than running the step.
What is the difference between a mock-up and a provisional?
A mock-up is a non-prepped bisacryl shell placed over natural teeth so the patient can preview the design in minutes. It comes off before the patient leaves the chair. A provisional is a long-term temporary bonded to prepared teeth and worn for weeks. The mock-up tests the design. By contrast, the provisional tests the design plus the preparation plus the occlusion.
Do I need digital smile design software to run this workflow?
No. The workflow runs on a 2D smile mockup prepared in slide software or an image editor. DSD software makes the design phase more precise and faster, especially on multi-unit cases. For a two- or four-unit case, a careful 2D design and a hand or printed wax-up can produce the same clinical result.
How should the dentist and the lab divide design responsibility?
The dentist owns the clinical case: midline, incisal edge position, VDO, occlusal scheme, and final patient approval. The lab owns the fabrication: ceramist choice, material layering, and surface texture. On a Signature case we expect a named ceramist to call the dentist with any judgment call the records leave open.
What is a bisque try-in and when is it worth the extra visit?
A bisque try-in is a visit where the lab delivers ceramic restorations after the first firing but before final glaze. The dentist verifies fit and shade and sends specific stain or glaze notes back to the ceramist. It is worth the extra visit on any anterior case where shade is critical and on multi-unit cases where symmetry matters. Posterior single-unit zirconia rarely needs it.
What is the most common reason smile-design cases need a remake?
Incomplete communication at the mock-up or shade stage. Either the patient did not approve the mock-up in a photograph, or shade information was a tab name on the Rx with no supporting photographs. Both failures are preventable with a records packet and a mock-up photo set complete before the case moves forward.
Does Peak Dental Studio handle the full smile-design workflow for outside practices?
Yes. Peak accepts cases from any practice at any phase of the workflow. The common entry point is at records: the dentist sends photographs, scans, and a prescription, and Peak returns a digital design and wax-up for mock-up try-in. From there the lab fabricates the prep guide, provisional, and final restoration under one named ceramist. See Peak’s cosmetic dental lab page for the full service list.
Have a Smile-Design Case? Send Peak the Records
Peak Dental Studio is an independent U.S. dental lab in Pleasant Grove, Utah. Signature Case Ownership means one named ceramist owns your smile-design case from the first wax-up through final stain. No subscription. No monthly minimum. No contract.
Send a Sample Case · See Signature Veneers · Peak Cosmetic Lab
About the author: Dr. Kellen McWhorter is a prosthodontist and the clinical director at Peak Dental Studio. His work focuses on full-arch implant restorations and esthetic ceramics. Email support@peakdentalstudio.com or call (801) 850-8758.
Before you go: Get Peak's 2026 price book.
Send me the price book